Various issues related to population of the STAC catalogue:

  1. NaN values in the Sentinel-2 viewing geometry: https://esa-cams.atlassian.net/browse/GSANOM-15086

    Coordination desk reply:

    This product is absolutely normal with respect to the current IPF implementation. It is really small as only few pixels from the datastrip intersect this tile as you can see in the CDSE and QGIS screenshots attached (the rainbow effect visible for the TCI displayed in QGIS is normal, and due to the fact that the different spectral bands do not share exactly the same footprint).

    A consequence of this very limited intersection between the tile footprint and the datastrip footprint is that we get only NaN viewing incidence values for several bands in the tile metadata, resulting in NaN mean viewing incidence values for these bands. This is because the grid on which the viewing incidence values are computed is very coarse (5 km x 5 km). Then this behaviour could happen sometimes for this kind of products (with limited intersection between the tile and the datastrip), and did happen before.

...